banner



How To Fix Code 11 On U-line Ice Maker

This article outlines U-line refrigerator mistake codes yous will commonly notice. So read to know what they mean and what to practise about them.

U-line refrigerator error

U-line Refrigerator Error Codes – Quick Fix

Here are the mistake codes in a U-line fridge and how to set them:

1. E1, ER

When you see this mistake code, you know that thermistor ane is open up. This means that there is a failure with the thermistor. Then it will not be able to accurately read the temperature using its resistance.

Test the resistance of the thermistor with a multimeter or ohmmeter. You lot should go the accurate resistance value from the refrigerator'southward tech sheet or search the user manual for instructions. If the thermistor does non have the right resistance value, it means the component is non operation. So, supercede it with a new ane.

2. E2

This error code signifies that thermistor 1 is shorted. If the thermistor is shorted, it means it has completely failed and may pose a hazard if you do not supercede it. And then, use the fridge'southward model number to detect and install a suitable replacement role. Alternatively, have an apparatus technician do the task.

3. E3

Y'all come across this error code when the lesser drawer or the refrigerator'south main door is open for upward to xx minutes or more. It is possible you or someone else did not close the door afterward the last use. It is also possible that the door does not shut well because of a weak or dirty door gasket.

An audible alert accompanies this error code; the alarm is the door open alarm to let y'all know you need to close information technology. Check to come across if anything is keeping the door from endmost tightly. Rearrange items inside the refrigerator to allow the door to shut tightly.

And check the door seal to exist sure information technology is still sealing properly. If the master door or freezer drawer closes well, this mistake lawmaking will automatically reset itself.

4. E4

The E4 mistake lawmaking tells you lot that the compressor did non have a break between the get-go of ane cycle and the showtime of another. That means it ran 100 percent. This could be equally a effect of muddy condenser coils, faulty start relay, or bad condenser fan.

Yous tin can apace inspect the coils; if they are dirty, apply a vacuum cleaner to remove the dirt. Ensure you repeat the process every 6 months to keep the appliance in summit shape. If the problem persists after cleaning the coils, remove the relay from the compressor'south side and shake it.

Shaking the relay is one way to test it; if it rattles, information technology is broken and needs a replacement. All the same, not every type of relay works this mode. So, if information technology does not rattle, it does not mean the relay is still working. Use a multimeter to run a continuity exam between the start and run terminals. Replace the relay if you discover no continuity.

Just if all of the above checks out, the condenser fan may be defective. And if the fan is defective, the compressor may overheat, especially if the coils are muddied or the fridge constantly runs. Turn the fan blade by hand; if stiff, it may be that the shaft needs oiling or the bearings are worn.

Use penetrating oil on the shaft and permit information technology to blot for a few minutes. And then, turn the fan blade again; if it remains stiff, the problem is with the bearings. That ways you lot need to supersede the motor. However, if everything seems to piece of work well, test the motor's continuity using a multimeter and supersede it if at that place is no continuity.

five. E5, E6

This error code indicates that thermistor 1 is not in range. Then, the absurd temperature of the refrigerator cannot be maintained because it is loftier.

Clean the condenser coils and clean it regularly, at least every iii months. This volition help maintain the cool temperature of the refrigerator. This is a skillful reason why the temperature is affected.

Additionally, call a qualified technician to take a look at the thermistor which is out of range. That is if you cannot find it yourself and prepare information technology.

6. E7

This error code means that thermistor 2 is shorted or is open up. The thermistor needs to be replaced. If yous tin can replace it yourself, do merely if non, take a fridge technician replace it for you lot.

297110400 Refrigerator Thermistor Replacement 12 Month Warranty

Buy this thermistor on Amazon

7. E8

Thermistor 3 is shorted or open if you meet this error code displayed on the console. This means that the thermistor needs to exist replaced. Have a fridge technician supersede it or do it yourself if you tin can.

8. E9

When you see this mistake lawmaking, it means that thermistor 4 is open up or shorted. In other words, the thermistor is no longer constructive. It is of import to replace the lacking thermistor.

nine. E10

This error code indicates that the top drawer of the refrigerator has been open up for more than 20 minutes. Exist sure to close the drawer tightly.

Additionally, check to be sure that nothing is keeping it from endmost fully and rearrange the contents of the drawer to make information technology easier to shut. Once the drawer closes well, the error lawmaking resets itself.

This error code applies only to U-line refrigerator with drawers and the lawmaking is accompanied by an audible alarm.

Bank check out these other articles…

  • Samsung Refrigerator Dispenser Problems [Solved]
  • Samsung Refrigerator Mistake [How to Set up]
  • Whirlpool Refrigerator Error [Solved]
  • Viking Fridge Error [Quick Ready]
  • Zanussi Refrigerator Error [Solution]
  • Westinghouse Refrigerator Error [How to Set]

10. E11, EE

At that place is an error with the retentivity of the refrigerator when you see this error code displayed. Contact a qualified refrigerator technician or a U-line service agent for assistance in fixing this trouble.

11. P1

This error lawmaking ways that the circuit of the pump is open up. This has to exercise with the ice maker and so applies to U-line refrigerator models with ice makers. Yous tin asking the service of a qualified refrigerator engineer from U-line or any other professional fridge technician to ready this problem.

Reminder

Switch the refrigerator off before touching any part of it for diagnostics or repairs. This is an important first footstep in guild to keep you and the refrigerator condom.

Become Instant Assistance — Ask An Experienced Verified Appliance Technician

Demand expert assistance? Click here to use the chat box on this page to speak with a verified appliance technician right away. No need for expensive in-home service calls. No appointments. No waiting.

Source: https://refrigeratorsreviewed.com/u-line-refrigerator-error-how-to-fix/

0 Response to "How To Fix Code 11 On U-line Ice Maker"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel